<track id="j5dvn"></track>
<video id="j5dvn"></video>

      <delect id="j5dvn"><noframes id="j5dvn">
        <em id="j5dvn"><var id="j5dvn"></var></em>
        <mark id="j5dvn"><progress id="j5dvn"><i id="j5dvn"></i></progress></mark>

        <p id="j5dvn"></p>
        <noframes id="j5dvn"><font id="j5dvn"><nobr id="j5dvn"></nobr></font>
        <address id="j5dvn"></address>
          <big id="j5dvn"><address id="j5dvn"><rp id="j5dvn"></rp></address></big><font id="j5dvn"></font>

            專利快速測定儀一表多用可做為cod測定儀、氨氮測定儀、總氮測定儀、總磷測定儀、重金屬測定儀,專利產品【測定儀一年保護、終生免費維護】
            028-87843859 13348859961vip@5117.info

            總氮去除投加乙酸鈉

            [導讀]:5117水質測定儀提供"總氮去除投加乙酸鈉"產品,廠家直銷總氮去除投加乙酸鈉儀表,總氮去除投加乙酸鈉測定儀價格優惠,總氮去除投加乙酸鈉一年包換總氮去除投加乙酸鈉終生保修,找總氮去除投加乙酸鈉儀器到總氮去除投加乙酸鈉廠家批發價格。

            總氮去除投加乙酸鈉信息


            總氮去除投加乙酸鈉
            找總氮去除投加乙酸鈉信息尋總氮去除投加乙酸鈉產品,到5117水質測定儀,專業“總氮去除投加乙酸鈉”測定儀廠家,提供優質總氮去除投加乙酸鈉儀表、總氮去除投加乙酸鈉售后服務專業、總氮去除投加乙酸鈉價格實惠

              

            化學發光定氮儀/總氮測定儀 型號:DP-3000

            化學發光定氮儀/總氮測定儀特點:

            化學發光定氮儀是根據化學發光原理與計算機技術相結合開發的新一代精密實驗儀器。儀器執行標準:SH/T 0657-2007、ASTM D4629-1996 液態石油烴中痕量氮測定法(氧化燃燒和化學發光法)
            可廣泛應用于石油、化工、煤碳、科研院校等行業,是目前國內外較為先進的氮含量分析手段

            化學發光定氮儀是目前zui先進的總氮分析儀器,廣泛應用于測定成品油、原油、餾分油、石油氣、塑料、石油化工、食物以及水中等產品中總氮含量。與國內外同類儀器相比,具有操作簡便,性能穩定可靠,分析精度高,重復性好等優點

            •  
            •  
            •  
            •  

             儀器具有極高的靈敏度、線性度和抗干擾能力、分析結果精確可靠。

            化學發光定氮儀/總氮測定儀標準:

            SH/T 0657-2007液態石油烴中痕量氮測定法(氧化燃燒和化學發光法);

            SH/T 0704-2001石油及石油產品中氮含量測定法(舟進樣化學發光法);

            GB/T 17674-1999原油及其產品中氮含量的測定(化學發光法);

            ASTM D5762-2010用船進氣化學發光法測定石油和石油產品中氮的試驗法;

            ASTM D4629-2010 注射/插入氧化燃料和化學發光法測定液態石油碳氫化合物中痕量有機結合物氮的標準試驗方法;

              ASTM D6069-2001通過氧化燃燒和還原壓力化學發光檢測法測定航空用碳氫化合物中痕量氮的標準試驗方法。

            技術參數:

             樣品種類:液體、固體和氣體(需配相應的進樣器)

             測定方法:化學發光法(N)                

             測定范圍:0.1mg/L~5000ppm~百分含量

             檢測下限:0.1mg/L(氮元素)

             重復性誤差:①0.1mg/L≤X<1.0mg/L;   ≤±0.1mg/L;

                           ②1.0mg/L≤X<100mg/L,    ≤10%

             ③100mg/L≤X≤10000mg/L,  ≤5%              

             氣源要求:高純氧氣:99.98%以上            高純氬氣:99.98%以上

             控溫范圍:室溫~1100℃

            化學發光定氮儀概述

              

                哈?偟噭┲饕墙涍^電子式溫濕度監測儀器的自動化不斷提高的代表,并在原先的基礎上進行設置了標準接口,能夠與控制計算機和除濕、降溫、通風等設備進行互聯,從而出現了一體化的溫濕度自動測控系統,這一系列的運用比較的廣泛,一體化溫濕度測控系統形式多種多樣,整體性能主要取決于所選用的硬件設備。分析過程中只需將規定量的水樣注入試劑或將試劑溶解在規定量的水樣中,按程序操作后,將樣品瓶放入分光光度計或比色計中(預存有標準曲線)直接讀數便可得到精確的測試結果。將樣品信息輸入到控制單元中,自動進樣器向消解及分析單元自動進樣。自動沖洗以及針式樣品混合功能,保證了測量結果的準確性以及取樣的無污染化。

                提高零件表面的硬度、耐磨性、導電性和導磁性能,還可改善某些金屬的釬焊性。抽取定量的樣品和試劑并定時進行2點校正和系統清洗。哈?偟噭┩ㄟ^一個保持45℃的加圈,然后流到反應槽。一路空氣確保樣品試劑完全混合并防止樣品管路和反應槽中的沉積。反應槽有一個溢流口以維持在一個恒定的液位。當系統改變模式時,控制器將打開槽底部排水溝以沖洗試劑槽,結合定期的清洗回路將大大減少固體和細菌在系統內的形成。在管的端部緊貼pH電極敏感膜處裝有氣疏水半滲透膜,使內電解液與外部試液隔開。樣品溶液中溶解的氣體,通過疏水半滲透膜擴散進入pH電極敏感膜表面與疏水半滲透膜之間的極薄的內電解液液層內,直到試樣和極薄液層內該氣體分壓相等。薄層內離子活度的變化可由復合電極檢出,所以電極電位與樣品中氣體分壓或濃度有關。

            哈?偭卓偟诰分析儀器操作指南npw160維護試劑

              

            自來水中氯離子對水的作用及影響

            在水中添加氯,可以作為一種有效的殺菌消毒手段,在世界上被大部分自來水廠所使用。而如果要保持水中微生物的指標保持在安全指標內,那么市政自來水中必須保持一定量的余氯。當氯和有機酸等反應時,會產生許多的致癌副產品,比如三氯甲烷等。水中含氯一旦超過一定量,本身也會對人體產生許的多危害,而且還會帶有非常難聞的氣味,俗稱“漂白粉味”,F在大多數的專家達成共識,人們飲用水中含有超標氯與得癌幾率有一定的關系。

            如果將自來水加以煮沸,水體中含有的一種致癌物質——三氯甲烷,將比冷水致癌率增加三到四倍,因此我們日常所飲用的咖啡、茶或湯,經加溫沸飲用后;我們的體內既增加了三到四倍的致癌物。

            自來水中氯對人體的危害

            我們日常生活中所飲用的自來水,在飲用之前必需先將其中余氯帶來的殘留毒素予以完全清除。氯是一種揮發性的無機化學物質,曾在第一次世界大戰中用來當做毒氣使用,氯對皮膚及毛發的蛋白質造成傷害,破壞其自然的電解質反應;在自來水加氯,對于洗衣服來說無所謂,但明顯是不適合當飲用水或是洗澡的。

            圖:氯的危害-余氯測定儀-深圳丁當科技有限公司

            氯加入水中之后,會使人的頭產生干燥、斷裂、分岔等不好的現象,也讓人的皮膚顯示不正常的白色,層脫落甚至產生奇癢無比的皮癬等過敏癥。經過研究表明,水中含有過量的余氯,對小孩和老人家,或者是對氯產生過敏的人,傷害性會更加明顯,直接性的負面影響,因此對水中含氯量一定得嚴格控制。

            人們了解到水中的氯對人體的危害,加大了對水中氯的控制,目前市場上余氯測定儀的研發,使得人們能夠輕易方便的隨時測定水中含氯量,這就給我們的生活提供了便利,讓我們一起來呼吁,為了人類的健康,希望水廠積極響應國家號召,嚴格控制水體健康,讓我們的生活更加美好,健康每一個人。

            水中重金屬對環境和人體的危害

              

              中國總氮測定儀工業的發展方向,要盡量滿足不同種類、不同層次的多樣化市場需求,向用戶提供能夠提升品位、豐富內涵的技術裝備,是當今總氮測定儀行業企業的目標。“個性化設計”目標,是總氮測定儀行業企業的發展方向。
             

              目前,世界各國對總氮測定儀發展十分重視,集機、電、光、聲、磁為一體的高新技術產品不斷涌現。生產高效率化、資源高利用化、產品節能化、高新技術實用化、科研成果商業化已成為世界各國總氮測定儀發展的趨勢,這也是我國總氮測定儀業的發展方向。對于我國的總氮測定儀生產企業來說,不能求大求全,而應求精求專。美國、日本、意大利的總氮測定儀生產企業大部分規模不大,但專業化程度很高,從國際總氮測定儀發展的趨勢來看,中國的總氮測定工業僅靠增加資金投入、擴大生產規模的粗放式經營已不能滿足形勢發展的需要,我國的總氮測定設備生產已進入調整產品結構、提高開發能力的新時期。技術升級、產品換代、加強管理是行業發展的重要課題。
             

              在產品結構上,總氮測定儀行業應以市場為導向,改變目前以低技術含量為主、低水平競爭的狀況,淘汰一批低效高耗、低檔次、低附加值、勞動密集型的產品,努力開發生產高效低耗、產銷對路的大型成套設備和高新技術產品。
             

              在設計思路上,結構設計的標準化與模塊化應為同一種模式,這樣可以利用原有機型進行模塊化設計,以便在較短時間內開發出新機型,提高產品更新換代的速度,同時也有利于總氮測定儀的專業化生產。在生產制造上,專業化生產已成為趨勢。國際總氮測定儀廠商都十分重視總氮測定儀零部件的通用性,一些通用標準件不再由總氮測定儀廠生產,某些特殊的零部件則由高度專用化的生產廠家生產,而真正的總氮測定儀廠在某種意義上只是組裝廠。而我國的總氮測定儀企業也不必做大做全,而應集中力量發展核心技術,提升產品的競爭優勢。
             

              市場經濟的開放,商品之間的競爭也更為激烈,效率也成為每個客戶追求的目標,我們國家在整個行業都起步比較晚,與世界同行業相比有很大的差距,總氮測定儀要趕超世界。我們國家的總氮測定儀必須迅速發展壯大,讓我們國產設備也無人超越。
             

              北京科諾是國內起步zui早的總氮測定儀生產企業之一,這十幾年年來,我們在堅持總氮測定儀質量的基礎上,一直緊跟時代發展腳步,不斷進行總氮測定儀技術的改革以滿足市場的需要。我們zui先把自動化技術融入到總氮測定儀的生產過程中,通過不斷地嘗試研發了總氮測定儀?偟獪y定儀zui大的優點就是自動化程度高,能充分提高企業的總氮測定封口的效率,為企業節省了不小的開銷。根據國內總氮測定儀企業的實際情況自己獨立研發出真正適合我國企業的總氮測定儀,幫助企業增強了市場競爭力。
             

              總氮測定儀譜寫了總氮測定儀行業新的開端,給我們創造了高效時代,大大提高了我們的總氮測定效率,壓縮了我們的總氮測定成本,給我們的廣大客戶打造了暴利時代,F在我們國產設備也不再憑借低廉的價格來掠奪市場,我們靠的是技術來征服客戶。我們的國產設備也進入了拼科技的時代。
             

              科技成就未來,有了科技的大力支持,我們的各項技術也逐步的成熟,相信總氮測定儀的未來可以更加美好。

            總氮測定方法

              

            COD.氨氮.總磷測定儀/COD、總磷、氨氮檢測儀/三參數水質分析儀 型號:TDCHM-301


            技術指標 
            1. 測量范圍: 
            COD:5~2000mg/L(分為二個量程: 5~200 mg/L、200~2000 mg/L)。 
            氨氮:0.02~10mg/L 
            總磷:0.00~10mg/L 
            2. 示值誤差: 
            COD:示值誤差為≤±5 % 
                 氨氮:≤±3%(F.S) 
                 總磷: ≤±5%(F.S) 
            3.  重復性  :≤3% 
            4.  抗氯干擾:≤1200mg/L(COD測定) 
            5.  溫控系統:室溫~180℃可設定,COD消解溫度為165℃,總磷消解溫度120℃。 
            6.  控溫精度:±0.5℃ 
            7.  消解時間:COD為10min,總磷為30 min 
            8.  光學系統:610nm(COD)、420nm(氨氮)、630 nm(總磷) 
            9.  光學穩定性:儀器吸光值在20min內漂移小于0.002A 
            10.  批處理量:16個水樣 
            11.  外形尺寸:COD氨氮總磷測定儀 266mm×200mm×130mm 
                                  消解儀(DIS-16型)216mm×320mm×146mm 
            12.   重量:  主機kg   消解器kg 
            13.   功耗:  <500W 
            14.   正常使用條件: 
                  ⑴ 環境溫度:5~40℃   ⑵ 相對濕度: ≤85% 
                  ⑶ 供電電源: AC(220±22)V;(50±0.5)Hz 
                  ⑷ 無顯著的振動及電磁干擾,避免陽光直射。 
            儀器特點 
            1.  消解儀與測定儀分開,不影響測定。溫度PID自動控溫、計時。 
            2.  操作省時。COD消解只需10min。 
            3.  冷光源、窄帶干涉光學系統,光學穩定性好。 
            4.  自動調零功能。 
            5.  斷電保護功能。 
            6.  可各保存COD、氨氮及總磷的標準曲線10條及99個測定值 
            7.  LCD大屏液晶顯示,操作方便直觀。

            COD?氨氮?總磷三參數測定儀的用途

              

            《水污染防治法》第二十條規定:國家實行排污許可制度。直接或者間接向水體排放工業廢水和醫療污水以及其他按照規定應當取得排污許可證方可排放的廢水、污水的企業事業單位,應當取得排污許可證;城鎮污水集中處理設施的運營單位,也應當取得排污許可證。禁止企業事業單位無排污許可證或者違反排污許可證的規定向水體排放前款規定的廢水、污水。

            排污許可制度是落實企事業單位總量控制要求的重要手段,通過排污許可制改革,改變從上往下分解總量指標的行政區域總量控制制度,建立由下向上的企事業單位總量控制制度,將總量控制的責任回歸到企事業單位,從而落實企業對其排放行為負責、政府對其轄區環境質量負責的法律責任。
            排污許可證載明的許可排放量即為企業污染物排放的天花板,是企業污染物排放的總量指標,通過在許可證中載明,使企業知曉自身責任,政府明確核查重點,公眾掌握監督依據。一個區域內所有排污單位許可排放量之和就是該區域固定源總量控制指標,總量削減計劃即是對許可排放量的削減;排污單位年實際排放量與上一年度的差值,即為年度實際排放變化量。
            改革現有的總量核算與考核辦法,總量考核服從質量考核。把總量控制污染物逐步擴大到影響環境質量的重點污染物,總量控制的范圍逐步統一到固定污染源,對環境質量不達標地區,通過提高排放標準等,依法確定企業更加嚴格的許可排放量,從而服務改善環境質量的目標。

            企業應當加強環保意識|重金屬測定儀|總磷測定儀

              

            氨氮快速測定儀_氨氮快速測定儀的售后服務

            丁當客服:您好,我是丁當科技的在線客服,請問有什么可為您服務的?

            訪客:您好,貴公司有cod快速測定儀和氨氮快速測定儀是吧?

            丁當客服:您好,有的,您是想要購買cod測定儀和氨氮測定儀這兩款儀器嗎?

            訪客:是這樣的,我們公司以前的采購通過代理商在貴公司這里購買過一臺氨氮測定儀,有兩年時間了,現在還在用,因公司業務的拓展,現不僅要測定氨氮,還要測定化學需氧量cod,所以想在購買一臺cod測定儀,現在這個采購離職不在我們公司了,我們聯系不上那個代理商了,所以我們就直接聯系貴公司了。

            丁當客服:嗯,可以的,貴公司對COD測定儀的量程有什么要求嗎。

            訪客:大概在3000mg/L左右,聽說買cod快速測定儀還需要另外買cod消解儀是吧,你們這有嗎。

            丁當客服:您好,是這樣的,我們這邊cod測定儀和cod消解儀都是配套賣的,所有的報價,需要消解的都是含消解儀在內的整套儀器價格,另外是含稅含運費的。

            訪客:嗯,這樣很好,就不用我再專門去采購cod消解儀了,您稍后給我做個報價單吧,我的QQ是……。

            丁當客服:好的,報價單已發給您,你看看有什么問題沒有。

            訪客:嗯,基本上沒問題,那個售后說的是免費維護一年是嗎?

            丁當客服:是的,非人為因素造成的任何損壞,我們公司承諾為其免費維修。

            訪客:可以,無所謂了,這個氨氮測定儀用了兩年了也沒出過問題,所以就直接過來買了。

            丁當客服:謝謝您的信任,丁當將更加努力的。

            訪客:對了,如果我們以后還需要測定其他的參數,比如總磷、總氮之類的,那到時候還是在你們這里購買儀器嗎?

            丁當客服:是的,總磷測定儀、總氮測定儀這里都有的,若到時候還要測定總磷、總氮等參數的話,到時候不用購買新的儀器了,只需要將cod快速測定儀返廠,我們將儀器進行改裝,將幾個參數整合到一臺儀器上就行了,到時候僅需要付點成本價就成,十分經濟。

            訪客:那不錯啊,行了,就按照這個價格把款打過去是吧,價格挺公道的,有問題再找你。

            丁當客服:好的,感謝您的理解與支持。

            氨氮快速測定儀價格

              

            摘 要 采用CleverChem200 型全自動間斷分析儀快速測定煉油廢水中氨氮的含量,考察了方
            法的測量條件, 結果表明:在取樣量40μL、試劑R1、R2、R3分別為、160μL、50μL、30μL、反應時間
            8min,同時與蒸餾滴定法進行比較,在氨氮濃度0.10~25.0 mg·L-1 范圍內,zui大相對標準偏差為3.3%,
            zui大相對誤差為5.1%;厥章试92~106%之間。本方法具有速度快,每小時能分析100 個樣品、同
            時樣品和試劑的用量少,有效降低分析成本和實驗室的二次污染,特別適合于多樣品、多項目的分
            析。
            關鍵詞: 全自動間斷分析技術;煉油廢水;氨氮;蒸餾滴定法


            1 前言
            全自動間斷分析技術是zui近幾年發展起來的一種自動化程度高、分析速度快、采用微型反應的
            一門全新的分析技術,其每小時可以完成100 個以上樣品參數的測定,在國內已廣泛應用于海水、
            煙草等領域中氨氮、總磷、磷酸鹽、氯化物、硝酸鹽、亞硝酸鹽、硅酸鹽、六價鉻、揮發酚、硫化
            物等指標的監測[1]。但由于煉油污水水質比較復雜,干擾嚴重,全自動間斷分析技術在煉油化工污
            水中的應用研究還很少見到報道。本文研究了采用CleverChem200 型全自動間斷分析儀直接測定煉
            油污水中的氨氮,取得了良好的效果,該技術由于是機器人取樣,準確度和重現性都較好,特別適
            合于多參數、多水樣的測定,有效降低了工人的勞動強度,由于采用微型反應,化學試劑和樣品的
            量都是以微升計算,降低了分析成本,同時也降低了實驗室的二次污染。值得在各行業中推廣應用。
            2 實驗部分
            2.1方法原理
            在堿性條件下,微量水樣中的氨分子與微量次氯酸鹽(或二氯異三聚氰酸鈉)、微量水楊酸鈉
            發生反應,生成顯色的配合物,整個反應是在硝普鈉的催化下進行,在CleverChem200 全自動間斷
            分析儀中,在660 nm 波長下比色測定,自動得到分析結果[2]。
            2.2主要儀器和試劑
            2.2.1主要儀器
            CleverChem200型全自動間斷分析儀(德國生產)。
            2.2.2主要化學試劑
            R1 緩沖溶液:溶解3.73gKCl、 1.3gNaOH、5.5g酒石酸鉀鈉(NaKC4H4O6·4H2O)于400mL蒸餾
            茂名石化科技攻關項目:(15650000-12-ZC0607-0004)
            作者簡介:(1978-),女,本科,工程師,主要從事水質監測的研究工作。
            2
            水中,定容至500mL(或減量配制),搖勻。冰箱4℃冷藏可保存數周。
            R2 水楊酸鈉溶液:溶解75g 水楊酸鈉 (NaC7H5O3) 于300mL 蒸餾水中,加入0.15g 硝普鈉
            (Na2Fe(CN)5NO.2H2O)溶解并定容至500mL(或減量配制),搖勻。盛裝于琥珀色容器,冰箱4℃冷
            藏可保存3 周以上。
            R3 二氯異三聚氰酸溶液:溶解1g 二氯異三聚氰酸鈉于蒸餾水中,定容至500mL。
            標準儲備溶液:溶解3.819 g 無水氯化銨(NH4Cl),在105°C 下干燥,用蒸餾水稀釋至1000mL,
            配制成1000 mg·L-1NH3-N.標準母液(或根據需要減量配制)。該母液亦可從國家標物中心購買。
            標準溶液(NH3-N 濃度為25.00 mg·L-1: 準確移取標準儲備液6.25mL,定容250.0mL。
            2.3 實驗步驟
            2.3.1 蒸餾滴定法
            分取250ml 水樣(如含氨氮含量較高,分取適量并加水至250ml,使氨氮含量不超過2.5mg)。
            移入凱氏燒瓶中,加數滴溴白里酚藍指示液,用氫氧化鈉溶液或鹽酸溶液調節PH 值為7 左右。加入
            0.25g 輕質氧化鎂和數粒玻璃珠,立即連接氮球和冷凝管,導管下端插入硼酸吸收液液面下,加熱蒸
            餾,至餾出液達200ml 時,停止蒸餾,用標準鹽酸溶液滴定到終點,計算出氨氮的含量[2,3].
            2.3.2 CleverChem200 型全自動間斷分析儀法
            (1)開機(按下機器后背的電源和機器前的起動鍵),打開電腦,點擊工作站軟件,則系統自動進
            入清洗和預熱階段(一般設定為37℃),當出現“嘀--”響聲時,預熱和清洗結束,可以進入下一步
            工作[1];
            (2)把標準溶液、蒸餾水和樣品分別裝入特制的樣品杯中,置于樣品旋轉盤中;把試劑R1、R2、
            R3分別裝入特制的試劑盒中,置于試劑旋轉盤中,記好對應的位置[1];
            (3)工作站軟件的設置
            ①測量條件的設置 測量條件主要是考察取樣量、試劑R1、R2、R3的加入量、反應時間等;
            ②工作曲線濃度設置 標準溶液(NH3-N濃度為20.00mg/L)稀釋倍數分別為: 1:1、1:2、1:5、1:10、
            1:30,則對應工作曲線濃度為:25.00、12.50、5.00、2.50、0.833、mg/L,(或根據具體情況改變稀
            釋倍數)。
            3 結果及討論
            3.1 水樣的前處理
            水樣如果渾濁、有沉淀物,則過濾后可直接測定;如果含鈣和鎂離子濃度過高,可能干擾反應,
            可加適量固體EDTA 掩蔽干擾;如果樣品有顏色,且在測定波長范圍內有吸收,則不能直接測定,必
            須蒸餾后再測定[2,3]。
            3.2 測量條件的設置
            測量條件主要是考察取樣量、試劑R1、R2、R3的加入量、反應時間等。樣品量可根據樣品濃度的
            大小在1-300μL之間改變,氨氮濃度高的樣品,取樣量適當減少,反之,氨氮濃度低的樣品,則取樣
            量適當增加,這樣,可以使吸光度在一個合適的范圍,有效提高測定結果的準確度,但樣品取樣量
            不能超過300μL;試劑R1、R2、R3也可作相應調整,但總體積不應超過500μL。通過多次試驗,氨氮濃
            度小于25.00 mg·L-1的水樣,采用下表1的試驗條件可以得到滿意的結果。對于氨氮濃度高于25.00
            mg·L-1的水樣,可以采用自動稀釋水樣的方法達到測定要求。
            3
            表1 測量條件的設置
            Tab1: measurement condition settings
            樣品和試
            劑名稱
            樣品和試劑
            加入量/μL
            延遲時間/s 其它測量條件
            樣品量 40 36s 測定波長:660nm
            試劑R1 160 0s 測定方法:終點法
            試劑R2 50 36 線性:直線
            試劑R3 30 480s 試劑空白:不使用試劑空白
            3.3 工作曲線
            以標準溶液NH3-N濃度為25.00 mg·L-1,稀釋倍數分別為: 1:1、1:2、1:5、1:10、1:30,則對
            應工作曲線濃度為:25.00、12.50、5.00、2.50、0.833 mg·L-1,以表1的測量條件作圖,得到如下
            圖1的工作曲線,回歸方程為Y=0.0389x-0.0064,相關系數為r=0.9994。具有良好的線性關系。
            圖1 工作曲線
            Fig.1 Standard curve
            3.4新方法重現性和準確度試驗
            不同濃度的氨氮平行測定6 次,同時與蒸餾滴定法相比較,結果如下表2,由下表2 可看出:
            不同濃度下,相對標準偏差和相對誤差不同,但都能滿足要求,同時,新方法與蒸餾滴定法相比,
            相對標準偏差要小一些,這是因為新方法取樣和加入試劑都是全自動的,避免了人為因素造成的誤
            差,所以標準偏差要小一些。
            表2:新方法重現性和準確度
            Tab2: reproducibility and accuracy of the new method
            水樣氨氮
            濃度/mg·L-1
            本方法平行測定6 次結果
            / mg·L-1
            平均值
            /mg·L-1
            相對標準偏差
            / mg·L-1
            相對誤差
            /%
            蒸餾滴定法相對
            標準偏差/ mg·L-1
            19.87
            20.21 19.89 19.87
            20.35 20.71 19.41
            20.04 2.5 0.81 2.8
            1.985
            2.101 2.091 1.981
            2.109 1.976 1.980
            2.039 2.9 2.7 3.5
            0.0971
            0.1081 0.1010 0.1051
            0.0984 0.0978 0.0985
            0.1021 3.31 5.1 7.3
            4
            3.5 新方法回收試驗
            對不同水樣做加標回收試驗,結果如下表3,濃度在0.4898~37.443 mg·L-1之間,對應回收率
            在106~92%之間,可以滿足監測要求。method
            表3:新方法的回收試驗
            Tab 3: recovery test method
            水樣名稱
            新方法結果/
            mg·L-1
            加標
            /mg·L-1
            加標后結果
            / mg·L-1
            回收率/%
            A 池 37.443 10.00 46.82 93.8
            B 進 34.707 10.00 44.96 103.0
            O28 0.4898 1.00 1.39 92.0
            O1 池 26.361 10.00 35.89 95.3
            監控 5.636 10.00 15.21 95.7
            氣進 21.687 10.00 32.32 106.0
            總排 2.916 1.00 3.86 94.0
            3.5 兩種測量方法的比較
            全自動間斷微型反應分析技術與蒸餾滴定法對煉油污水的測量結果如下表4,由表4可以看出:
            對于不同取樣口的水樣,兩種測量方法基本一致。
            表4:兩種測量方法的比較
            Tab.4: a comparison of two measurement methods
            水樣名

            全自動間斷技
            術/ mg·L-1
            蒸餾滴定
            法/mg·L-1
            差值/ mg·L-1
            差值與蒸餾滴定
            法的比值/%
            浮2 29.150 30.30 -1.15 -3.4
            隔2 27.567 29.00 -1.02 -3.4
            B 出 33.201 33.60 -0.04 -1.2
            6#路 0.779 0.726 0.053 7.3
            4#凈化水 19.59
            1
            20.30 -0.71
            -3.5
            B 進 35.215 35.90 -0.68 -1.9
            A18 18.485 19.10 -0.62 -3.2
            O18 13.502 14.10 -0.60 -4.2
            O28 1.56 1.64 -0.08 -5.5
            O1 池 35.335 36.50 -1.16 -3.2
            含油 29.385 30.90 -1.51 -4.9
            4 結論
            (1)全自動間斷微型反應分析技術具有分析速度快、水樣、試劑用量少,降低分析成本、減少
            實驗室二次污染等優點;
            (2)全自動間斷微型反應分析技術應用于煉油廢水中氨氮的測定,其回收率在92~106%之間,
            能滿足水質監測的要求,可以在生產中推廣應用。
            5
            參考文獻:
            [1]深圳市朗誠實業有限公司全自動間斷化學分析儀. http://www.yi7.com/sell/show-171465.html.
            [2] 國家環保局水和廢水監測分析方法編委會.水和廢水監測分析方法[ M] . 4 版. 北京: 中國環境
            科學出版社, 2002.
            [3]穆季平,李紅娟.蒸餾-滴定法測定廢水中氨氮的方法研究.[J] 河南大學學報,2006,36(3):54-57.
            Automatic Analysis of Intermittent Determination of Ammonia
            Nitrogen in Sewage of Oil Refining Technology
            LIN Chunfeng1 CHEN Zongwei2 DENGYue1 LIN Peixi3
            1Quality Inspection Center of Maoming Company SINOPEC (Maoming 525000, China)
            2Shenzhen long Cheng Industrial Co. Ltd (Shenzhen 518029 ,China)
            3Guangdong University of Petrochemical Technology (Maoming 525000, China)
            Abstract by using the CleverChem200 automatic continuous determination of ammonia
            nitrogen in refinery wastewater analyzer, the measurement conditions, method results show
            that: in the sample volume was 40 μL, agent R1, R2, R3 respectively, 160 μL, 50 μL, 30 μL,
            reaction time 8min; and compared with steam flow titration, the ammonia concentration 0.10
            ~ 25 mg • L-1 range, the maximum relative standard deviation is 3.3%, the maximum relative
            error is 5.1%. The recovery is 92-106%.This method is rapid, hourly analysis of 100 samples,
            the sample and reagent consumption, reduce pollution two cost analysis and laboratory
            analysis, especially suitable for many samples, multiple projects.
            Keywords: automatic analysis of intermittent technology;refinery wastewater;
            ammonia nitrogen;distillation titration method
            :林培喜,:,
            :lpx2923

            關于化學發光定氮儀

               近年來,微波消解技術在我國得到了廣泛的推廣,市場上的產品選擇也越來越多,國外廠家與國產品牌之間的競爭態勢也越來越明顯。我們在論壇上一方面看到廣大用戶對國產品牌支持的呼聲很大,另一方面也看到國外廠家對國內品牌時有貶低之辭,以及國內廠家之間也相互拆臺,從而讓很多用戶對國產微波消解懷有不信任感。實在國內微波消解技術歷經二十年的發展已經取得了長足的進步,無論從品種、性能和應用方法上都完全能滿足國內各行業用戶的需要,某些型號的性能特點也可與國外同類產品相媲美。我們應該站在公正客觀的態度上對國內微波消解技術的現狀與遠景及其對我國分析測試技術的貢獻作一個正確的熟悉。

            國內微波消解技術起源于二十世紀八十年代,當時國外微波消解也剛起步不久,賣到中國的都是天價產品,國內市場難以接受,于是在當時的上海和北京幾乎在差未幾的時間都邁出了將民用微波爐改裝為國產微波消解儀的*步,奠定了國產微波消解技術的基礎。這些產品以其低廉的價格和實用的性能,讓很多國內的用戶有機會嘗試到這一技術所帶來的上風和方便。經過二十多年的發展演變,國產微波消解技術發生了重大變化。

            選購國產微波消解儀不容忽視的一點,那就是操縱的便利性

            很多用戶在選擇微波消解儀器時只注重安全性,忽略了操縱便利性。實在,大家都明白,用微波消解不就是圖個方便嘛。假如儀器操縱太復雜,工作環境和狀況得不到改善,同時運行用度高昂,那對我們的樣品前處理工作也不會提升太高的效率。不同的廠家對儀器和消解罐采用不同的控制技術和結構設計,從而導致了不同繁簡程度的操縱方法,用戶在選擇時不應盲目追求技術參數的差別不大的數字高低或小數點后多一位少一位,而更應從不同廠家的設計原理上往體會其操縱的便利性。實在,微波消解在儀器的選擇上還普遍存在這樣的誤區,大部分人以為消解反應罐越多越好,儀器國外的就是zui好的。殊不知,儀器在操縱的時候,反應罐的數目越多操縱程序就越復雜,固然儀器消化的時間不長,但冷卻、清洗、卸裝測控系統極為耗時,致使爐腔利用率一直偏低,因此,我們除了對儀器性價比的判別外,還需從操縱的便利性進行衡量。同時從售后維護和產品保修來看,國外產品因諸多銷售流程的原因使得操縱者在維修時用度很高,備件周期較長,若等不到備件干著急,對用戶的工作也會帶來很多不便。

            廢水檢測處理之水質標準

               COD國標回流恒溫消解儀雙風扇對流冷卻,可獨立控制,冷卻效果顯著。大屏幕液晶中文顯示,時間、功率都可調,用戶可自行修改、設定、保存。采用微晶加熱面板,紅外線加熱方式,升溫速度快且均勻,使用壽命更長.消解完成后,儀器自動鳴響提醒并停止加熱工作。節水節電熱輻射小,占用空間小。操作簡單,可有效的降低成本、提高工作效率。

            COD國標回流恒溫消解儀采用微機技術進行時序控制加熱方式,可選對6/10/12個磨口250ml錐形(直型大磨口) 瓶的全玻璃回流裝置同時進行加熱;達到節能、減低電力負荷、提高效率的目的。儀器使用玻璃毛刺回流管代替球形回流管,并以風冷和水冷技術取代自來水冷卻方式,既可節水并減少了放置空間又能使儀器標準化,同時還提高了儀器使用的安全性;加熱底板采用時尚的微晶光學板面設計理念,不但提高了樣品消解的準確度和精密度,而且提升了產品的美觀度。儀器的化學溶液配制、操作和COD的計算完全遵照zui新國標HJ 828—2017;注:對于≤50mg/L的COD水樣測定,當樣品濃度低時,取樣體積可適當增加;對于>50mg/L的COD水樣測定,可通過稀釋滴定劑和氧化劑來提高精確度;對于>700mg/L的COD水樣,須稀釋水樣濃度來完成結果測定;對于氯離子含量高的水樣,可參考zui新國標HJ 828—2017附錄A方法判斷測定。

            COD國標回流恒溫消解儀技術指標,測量時間:≤150分鐘(可依據用戶需求自行設定時間)測量誤差:鄰苯二甲酸氫鉀標準溶液(500mg/L)、相對標準偏不大于5.0%,工業有機廢水(500mg/L)、相對標準偏不大于8.0%。環境溫度:-5~40℃。顯示方式:液晶顯示。消解樣數:10個/批。消解時間:可依據用戶需求自行設定時間,1-999分鐘。風扇設置:自動/手動。加熱功率:1200W(AC 220V±22V,50HZ)。

            cod恒溫加熱儀一體式規劃

              

            氨氮測定儀性能特點:
            1、A型機采用納氏試劑比色法GB/T7479;B型機采用水楊酸光度法GB/T7418、ISO7150/1-1984。
            2、儀器可進行標準比色曲線的制作、儲存,并根據不同水體對象進行水質氨氮比色曲線調整。
            3、采用獨特光路比色系統,使儀器的可靠、穩定性有較大的提高。
            4、B型機采用二氯異三氰酸鈉替代氯酸鈉,使試劑溶液含氯穩定性和有效性大大增強。
            5、B型機采用獨特的樣品處理方法,縮短分析時間。

            氨氮測定儀技術指標

              

              總氮測定儀的功能特點概述

              總氮測定儀有6只試管孔,適合使用6只反應試管,儀器的加熱塊采用高密度鋁合金擠壓成型,具有熱容量大、熱阻小、加熱均勻等特點?偟獪y定儀采用智能型數字顯示溫度,隨意設定、自動恒溫、使用方便,控溫精度可達到200℃±1℃,設有數顯定時裝置,用戶可在一星期內任意調節計時時間。一體式遮光防塵蓋,使用試管免封口,試驗操作方便快捷。

              總氮測定儀功能:

              1.歷史查詢,選擇歷史查詢即可查詢歷史測量結果,按左/右鍵翻看測量結果,每個存儲的結果對應一個測量日期和時間,按確定鍵打印結果。在查詢界面下按住返回鍵幾秒后可清除記錄。

              2.調整時間,按左右鍵調整大小,按確定鍵移位,一直到最后一位后按確定鍵調整結束并返回。

              總氮測定儀特點:

              1.省時,總氮測定儀檢測所需時間不到1小時。

              2.總氮測定儀可自動調零和1~5點自動校準。

              3.標準光學玻璃樣槽互換性更強。

              4.總氮測定儀采用半導體發光器,其光源穩定壽命長。

              5.999次測量存儲功能。

              6.日期顯示功能,每次存儲對應一個日期和時間,方便查詢。

              7.可打印實驗結果。

              8.全中文菜單,總氮測定儀操作簡單易懂。

            總氮測定儀的發展優化升級

              

            ET1151M總氮試劑使用說明

            低量程:0 – 25mg/L

            1 打開ET3150B多功能消解器,加熱至105℃。

            2 打開兩支總氮消解管,分別加入粉包試劑A,蓋緊蓋子,上下搖動,使其溶解。注:可能不能完全溶解,不影響消解。

            3 *支內加入2.0ml去離子水作為空白,第二支內加入2.0ml水樣。

            4 將兩支消解管放入ET3150B消解器中消解30分鐘。

            5 消解結束后,將消解管取出,冷卻至室溫。

            6 打開消解管,分別加入粉包試劑B,蓋緊蓋子并搖晃使其溶解。

            7 打開消解管,分別加入粉包試劑C,蓋緊蓋子并搖晃約15秒。

            8 等待3分鐘后,再從消解管中取2.0ml已消解的空白和樣品分別注入兩支比色預裝管中,蓋緊蓋子,緩慢搖勻。

             注:搖勻過程中試劑放熱,應緩慢進行。

            9 待10分鐘后,調用ET1151M型測定儀中總氮低量程曲線*,將空白管放入調零后,放入樣品管直接讀數,得到水樣總氮含量。

             

            *注1:若使用其他型號可見分光光度計,用戶可自行建立工作曲線。將總氮標準樣品作為待測組,操作方法同上。

            測量波長調至420nm。

            注2:請勿丟棄粉包包裝袋中的干燥劑,每次使用后保持袋子密封。

            平時請將粉包放入干燥器中避光保存。

             

            ET1151M總氮試劑使用說明

            高量程:20 – 150mg/L

            1 打開ET3150B多功能消解器,加熱至105℃。

            2 打開兩支總氮消解管,分別加入粉包試劑A,蓋緊蓋子,上下搖動,使其溶解。注:可能不能完全溶解,不影響消解。

            3 *支內加入0.4ml去離子水作為空白,第二支內加入0.4ml水樣。

            4 將兩支消解管放入ET3150B消解器中消解30分鐘。

            5 消解結束后,將消解管取出,冷卻至室溫。

            6 打開消解管,分別加入粉包試劑B,蓋緊蓋子并搖晃使其溶解。

            7 打開消解管,分別加入粉包試劑C,蓋緊蓋子并搖晃約15秒。

            8 等待3分鐘后,再從消解管中取2.0ml已消解的空白和樣品分別注入兩支比色預裝管中,蓋緊蓋子,緩慢搖勻。

             注:搖勻過程中試劑放熱,應緩慢進行。

            9 待10分鐘后,調用ET1151M型測定儀中總氮低量程曲線,將空白管放入調零后,放入樣品管直接讀數,得到水樣總氮含量。

             

            *注1:若使用其他型號可見分光光度計,用戶可自行建立工作曲線。將總氮標準樣品作為待測組,操作方法同上。

            測量波長調至420nm。

            注2:請勿丟棄粉包包裝袋中的干燥劑,每次使用后保持袋子密封。

            平時請將粉包放入干燥器中避光保存。

            ET147210D目視氨氮離子濃度測定儀

               COD測定儀人性化設計精巧,測量操作簡捷快速,有效提高了COD測定的經濟性和安全性,降低了污染危害。ET99718是一款具有全量程水和廢水COD測量的專用儀器,廣泛應用于科學研究、高效實驗室、環保監測部門和各種應急檢測。

              COD測定儀性能特點:

              1. 用4孔消解器及可充電鋰電池加熱,加熱迅速,15分鐘即達160℃高性能超低功耗單片機,儀器待機時間久;

              2. COD測定儀操作省時,COD消解只需15min;

              3. 冷光源、窄帶干涉光學系統,光學穩定性好;

              4. COD-3030可保存曲線50條及199個測定值(帶時間標簽);

              5. COD-3031可保存曲線30條及500個帶時間標簽的記錄值;

              6. COD測定儀具USB端口,可以聯接電腦進行記錄讀取;COD-3031用大屏幕240×160的LCD顯示,操作方便直觀,

              7. COD-3030用大屏幕數碼LCD顯示。

              COD測定儀測定COD與標準化學方法具有如下優點:

              1、操作省時。重鉻酸鉀法一次樣品全過程分析需30分鐘,高錳酸鉀指數法全過程一次分析需40分鐘,而一般標準化學法測定一次全過程需半天左右。

              2、節省試劑。

              3、硫酸鐵不需要每天標定。因為滴定亞鐵離子是在陰極上電解產生,隨時用隨時電解,省去了試劑標定工作。

              4、對于氯化物含量較高的水體(一般為60mg/L以上)只需要用硝酸銀消除干擾即可。而在標準鉻法中對氯化物含量高于30mg/L的水體,需硫酸汞消除干擾,從而引入了二次污染。

              5、高含量、低含量都可以測定。COD測定儀可直接測定COD值低于800mg/L的水體,高于800mg/L的水體可稀釋后測定,水樣的COD值低于2mg/L~3mg/L時仍然可以測定,儀器靈敏度為0.3mg/L,這是標準法遠遠達不到的。

              6、從儀器本身來說滴定終點自動控制。這是由于儀器采用計算機判斷終點,結果直接顯示,準確可靠。

              7、COD測定儀可直接顯示水樣的COD值(單位mg/L),省去了繁鎖計算。本儀器適用于各省、市、縣環境監測站,廠礦環境監測部門污水處理廠,以及教學科研單位。



            279.html

            COD測定儀的幾種測量方法

               COD消解儀采用微機技術進行定時控溫加熱,可對8個消解錐形回流裝置同時進行加熱,加熱溫度0-200℃可調。國家標準GB11914—89分析方法規范地制定了水質化學需氧量COD(cr)的測定步驟,嚴格地規定了方法的加熱消解時間、溶液酸度、氧化劑和催化劑的用量等條件指標。顯而易見,水質COD(cr)的測定是有嚴格的條件規定,違背了條件規定進行操作,就會影響測定的準確性。

              COD消解儀使用中注意事項:

              1、COD消解儀在通電使用前,應先從回流管注水口處加入盡可能多的蒸餾水,以保證冷卻效果。

              2、對于污染嚴重的水樣,特別是工業污染源的水樣,可選取所需體積的1/10的試料和1/10的試劑,放入10×150mm的硬質玻璃試管中,用酒精燈加熱至沸數分鐘,觀察溶液是否變為藍綠色,若呈現藍綠色的話,應再適當的少取試料,重復以上實驗,直至溶液不再變藍綠色為止。以此確定待測水樣合理的稀釋倍數。稀釋時,所取廢水樣量不得少于5mL,如果化學需氧量很高(如工廠車間廢水),則廢水樣應多次稀釋。

              3、水樣的氧化回流應該在通風櫥內進行,以防氯氣之類的有害氣體妨礙操作人員的健康。

              4、混合均勻的水樣置250ml磨口的回流錐形瓶中,準確加入10.00ml重鉻酸鉀標準溶液及數粒小玻璃珠或沸石,連接磨口回流毛刺冷凝管,從冷凝管上口慢慢地加入30ml硫酸—硫酸銀溶液,輕輕搖動錐形瓶使溶液混勻。這一步驟是為保證濃硫酸溶于水的放熱反應造成體系溫度升高(約為90~95℃),不致使低沸點的有機物從上段管口逸出。(如甲醇沸點64.5℃,乙醇沸點78.3℃,甲醛沸點-19.5℃,乙醛沸點20.8℃),如果直接在敞開的條件下,加入濃硫酸的話,低沸點的有機物不經氧化逸出后,就會造成測定的結果數據偏低。舉個例說,若水中含有萬分之一的乙醇(100ppm),其對COD的貢獻為189mg/L(乙醇的理論COD為1.99g/g,測定CODcr的氧化率為95.2%),若在敞口三角瓶中直接加入濃硫酸的話,這一部分COD的損失還是較為可觀的。

              5、在COD消解儀的COD測定過程中產生的廢液中,含有濃硫酸、重鉻酸鉀、硫酸汞,屬于危險廢物,應該作為危險廢物專門處理,不得直接排往下水道中。

              6、由于方法的檢出下限為10mg/L,在10~30mg/L間的COD測定一定要采用0.025mol/L的重鉻酸鉀溶液氧化,再用0.01mol/L的硫酸亞鐵銨滴定,為了減少測定的相對標準偏差,建議加大試樣的取樣量,最好取50.0mL,平行測定也以三次以上為宜。為減少滴定誤差,可采用50.0ml的取樣量。

              7、測定低濃度COD的水樣時,還要考慮一些可能的影響因素,如用聚乙烯桶盛裝的蒸餾水或去離子水,隨著放置時間的增加,其COD值也會逐漸增加,有時甚至達到10mg/L以上。還有的實驗人員采用娃哈哈等純凈水(這是飲料中的所謂“純凈水”與分析意義上的“純凈水”有著本質的區別),替代蒸餾水或去離子水做空白,也會出現空白值增高的現象。

              8、每次實驗時,應對硫酸亞鐵銨標準滴定溶液進行標定,室溫較高時尤其應注意其濃度的變化。

              9、水樣回流消解結束后,加入蒸餾水或去離子水應從冷凝管上方緩慢加入,以便將附著在管內壁的揮發性有機物沖到試液中。

              10、滴定時不能激烈搖動錐形瓶,瓶內的試液不能濺出水花,否則影響測定結果。

              COD消解儀的化學溶液配制、操作和COD的計算完全遵照GB11914-89,低于50mg/L的COD水樣可通過稀釋滴定劑和氧化劑濃度來提高精確度,高于1000mg/L的COD水樣,可以通過水樣的比例稀釋來完成測定。



            265.html

            COD消解器如何提高效率

              

            AD-2A便攜式氨氮濃度測定儀  產品介紹:

             


            適用于大、中、小型水廠及工礦企業、生活或工業用水的氨氮濃度檢測,以便控制水的氨氮達到規定的水質標準。

            產品原理
            本儀器應用微電腦光電子比色檢測原理取代傳統的目視比色法。消除了人為誤差,因此測量分辨率大大提高。

            AD-2A便攜式氨氮濃度測定儀  產品特點:

            1.全中文菜單、微電腦,輕觸式鍵盤,LCD液晶數字清晰顯示,使用方便。
            2.采用分光光度的光電比色原理, 應用方便試劑,水樣放入試劑反應幾分鐘后即可讀數,數字顯示測定值。
            3.本公司特制的技術LED光源自動控制電路,光源穩定,解決了開機必須預熱問題。其光源壽命長達20年,開機時無需預熱,可直接使用。 
            4.主機內置打印機及大功率電池,可用于野外現場定量測量,充電4小時可連續使用4小時,即充即用。 
            5.儀器內存儲有全量程范圍內的標定曲線 ,具有斷電保護,標定數據不會丟失?勺詣诱{零和5點自動校正,數據有非線性處理及數據平滑功能,儀表最小讀數為0.01mg/L。
            6.融合多項自主設計成果,技術先進,符合國標GB/T5750-2006生活飲用水衛生標準。

            AD-2A便攜式氨氮濃度測定儀  技術參數
            測量范圍:0-50mg/L
            最小示值:0.01mg/L
            重復性:≤2%
            精度:≤±5%FS
            充電器:AC 220V 50Hz

             

            ALERT 2003 在線氨氮分析儀介紹

              

            產品簡介

              TN-3000型化學發光定氮儀國內zui先進的氮一體化分析儀器,廣泛應用于檢測液體、固體或氣體樣品中的氮含量。與國內外同類儀器相比,具有性能穩定可靠,分析精度高,重復性好等特點。
              樣品中的總氮含量是通過化學發光的方法被快速測量的。高精度的數據采集和計算機技術的應用為數據的采集、控制、處理提供了可靠的保證。

            技術參數
            基本參數:樣品種類:液體、固體和氣體
            測定方法:化學發光法
            樣品進樣量:固體樣品:1-20mg
                  液體樣品:5-20μL
                  氣體樣品:1-5mL
            測量范圍:0.1 ~5000mg/L
            測量精度:

            濃度值(ppm)

            進樣量(μL) RSD(%)0.1202551010501051001035000103

            控溫范圍:室溫~1300℃
            控溫精度:±1℃
            氣源要求:高純氬氣:純度99.995%以上 ,
                 高純氧氣:純度99.99%以上
            電  源:AC220V±22V,50Hz±0.5Hz,1500 W
            外形尺寸:主機:305(W)×460(D)×440(H)mm
                 溫控:550(W)×460(D)×440(H)mm
            重  量:主機:20kg
                 溫控:40kg

            主要特點
             1、靈敏度高:
              TN-3000系統采用化學發光法測定總氮含量,提高了抗雜質干擾的能力,避免了電量法對滴定池的繁鎖操作和因此帶來的不穩定因素,使得儀器的靈敏度大為提高。系統關鍵部件采用進口器件,使得整機性能有了可靠的保證。
             2、儀器執行標準為:
              SH/T 0657-1998 液態石油烴中痕量氮測定法(氧化燃燒和化學發光法)
              ASTM D4629-1996
             3、系統配置:
              標準配置:打印機+計算機+TN-3000系統+液體分析的附件
              其它可選件:固體進樣器、氣體進樣器
             4、操作簡便:
              基于Windows2000(XP,Me,98)的中文操作界面,使操作更為方便、快捷。您只需輕擊鼠標,就可完成所有的參數設置和條件選擇,由計算機控制數據的采集、處理、貯存及打印。

            關于稀釋的倍數

              

            購買了我們盈傲CNPN-4S II的客戶在使用總氮的時候常常會遇到測試總氮結果不穩定的情況,那么這是怎么造成的呢?今天我在這里給大家講解一下這個問題,主要是這么兩個原因:

            1.總氮試劑A堿性過硫酸鉀配制以后沒有很好的保存導致試劑A變質,造成空白的吸光度偏高,從而影響了實驗的結果;

            2.我們總氮測試使用的變色酸法是十分靈敏的,必須按照一下要求倒轉試劑管以避免測試結果偏低:將試劑管呈垂直方向,蓋子朝上拿放。倒轉試劑管時,請等待所有溶液朝下流到蓋子的方向,等待片刻。再將試劑管倒轉回原來的垂直方向,蓋子朝上,等待所有的溶液朝下流回試劑管底,這個過程是倒轉試劑管一次。

            在實驗的zui后一步顯色時我們必須要嚴格按照說明搖晃試管,而且顯色時間一定要嚴格按照說明書上的時間,不能過早也不能過久。

            (在配制上的問題我上一期已經說過了就不再重復了)

            只有按照我上述的操作,測試總氮是不會有問題的,還有就是測試總氮的時候不用抽煙!室內不要含氮過高,使用的蒸餾水必須不含氮。

             

            如果還有什么問題請和我。

            總氮水樣的稀釋方法

              

            • SN-200A型中氨氮測定的干擾和消除的方式
            • 1.樣品中含有懸浮物、余氯、鈣鎂等金屬離子、硫化物和有機物時,對比色測定有干擾,處理方法如下:
            • ⑴ 除余氯:
            • 加入適量的硫代硫酸鈉溶液(0.35%),每0.5mL可除去0.25mg余氯。也可用淀粉-碘化鉀檢驗是否除盡。

              ⑵ 凝聚沉淀

             取100ml水樣加入1 ml 10%硫酸鋅溶液和0.1~0.2ml 25%氫氧化鈉溶液,調節pH值至10.5左右,混勻。放置使其沉淀,用經無氨水充分洗滌過的中速濾紙過濾,棄去初濾液20ml。

            ⑶ 絡合掩蔽

            加入酒石酸鉀鈉溶液,可消除鈣鎂等金屬離子的干擾。

                   ⑷ 蒸餾法

            用凝聚沉淀和絡合掩蔽后,樣品仍渾濁和帶色,則采用蒸餾法。

            調節水樣的pH使在6.0-7.4的范圍,加入適量氧化鎂使呈微堿性,蒸餾釋出的氨被吸收于硼酸溶液中。

            1)蒸餾裝置:由500ml凱氏燒瓶及防噴頭和一個垂直放置的直形冷凝管組裝而成。冷凝管末端可連接一適當長度的滴管,使出口尖端浸入吸收液液面下約2cm。

                     2) 試劑:

            • 硼酸吸收液:20g/L溶液
            • 1mol/L鹽酸溶液
            • 氫氧化鈉溶液:40g/L溶液
            • 輕質氧化鎂(MgO):將氧化鎂在500℃下加熱,以除去碳酸鹽。
            • 0.05%溴百里酚藍指示液(pH6.0-7.6)
            • 防沫劑,如石臘碎片

            3) 步驟:

            • 蒸餾裝置的預處理:加250ml水于凱氏燒瓶中,加0.25g輕質氧化鎂和數粒玻璃珠,加熱蒸餾,至餾出液不含氮為止,棄去瓶內殘液。
            • 將50mL硼酸吸收液移入接收并內,確保冷凝管出口在硼酸溶液液面之下。
            • 分取250ml水樣(如氨氮含量較高,可分取適量并加水至250ml,使氨氮含量不超過2.5mg),移入凱氏燒瓶中,加數滴溴百里酚藍指示液,用氫氧化鈉溶液或鹽酸溶液調節至pH7左右。加入0.25g輕質氧化鎂和數粒玻璃珠,立即連接氮球和冷凝管,導管下端插入吸收液液面下。加熱蒸餾,至餾出液達200ml時,停止蒸餾。定容至250ml。

            4) 注意事項

            • 蒸餾時應避免發生暴沸,否則可造成餾出液溫度升高,氨吸收不完全。
            • 防止在蒸餾時產生泡沫,必要時可加入少許石蠟碎片于凱氏燒瓶中。
            • 5)低pH下煮沸蒸餾時,某些有機物很可能與氨同時被餾出,對測定仍有干擾,其中有些物質(如甲醛)可在比色前于低pH下采用煮沸而除之。
            • 水樣的保
            • 水樣采集在聚乙烯瓶或玻璃瓶內,并應盡快分析,必要時可加硫酸將水樣酸化至pH<2,于2~5℃下存放。酸化樣品應注意防止吸收空氣中的氨而遭致污染。
            SN-200A系列COD測定儀安裝及使用

              

            氨氮測定儀主要特點

              1、內存9條標準曲線,可修改保存

              2、具有數顯功能

            氨氮測定儀技術參數

                   1、測定范圍:0.02~60mg/L

              2、重復性:±5%

                 3、測量誤差:±10%

                4、直接測定時間:15~20min

              5、可同時測定4個水樣

              6、光度穩定性:≤ 0.001A / 10min

            相關產品有:CN-201型COD氨氮測定儀;NH-4N氨氮測定儀 ;

            氨氮測定儀的種類

              

            COD快速測定儀、氨氮快速測定儀引領水質檢測行業新方向

            水質檢測行業可以說是我國的新型行業,尤其是COD快速測定儀、氨氮快速測定儀、總磷快速測定儀、總氮快速測定儀等水質檢測儀器,在長期的發展中已經具備了與國際競爭的實力,“中國制造”已漸漸向著“中國研發”的方向發展,COD快速測定儀、氨氮快速測定儀等水質檢測儀器已經逐漸地引領水質檢測行業新方向。

            中國作為世界上的一個大國,一舉一動都受著全世界人民的關注,在經濟高速發展的過程中,水質環境問題已經成為全國人民關注環保的重中之重。水質問題逐漸影響著人民生活的同時,COD、氨氮、總磷、總氮污染已經為水質污染的代表,在與國際接軌的同時,我國水質檢測儀器的發展可謂是高飛猛進,有了長足的進步空間,并逐漸具備了與國際各國競爭的實力,尤其是COD快速測定儀、氨氮快速測定儀、總磷快速測定儀、總氮測定儀等水質檢測儀器,不管是在國內還是在國際市場上都有著不可忽視的占有率。

            圖:COD測定儀價格,氨氮測定儀價格

            根據統計數據表明,我國水質分析儀器的整體綜合技術水平是非常落后的,僅僅達到國際上80年代中期的綜合水平;在不斷地發展中,計算機技術與微電子技術在水質環保儀器中逐漸得到普遍的應用,已經達到國際90年代的綜合水平;而產品的數字化技術,在中國的應用為30%左右,達到國際綜合水平80年代中期的樣子。

            在水質儀器發展的過程中,一些儀器其實已經達到國際綜合水平,完全能夠滿足國內市場上的應用需求,不能說“崇洋媚外”,但目前有些人還是鐘愛國外水質檢測儀器的做法已經過時,在滿足實際需求的同時,若再購買國外水質檢測儀器,這無疑對資本是一個極大的浪費。比如COD測定儀價格,在國內市場上的價格也就一萬多元,而且測定數據準確有效,國家有關部門完全認可測定數據,而國外COD測定儀價格一般在兩萬元以上,甚至有的高達三萬以上,其實這還不是最主要的,對COD快速測定儀、氨氮測定儀來說,購買儀器之后的測定過程中所需的化學藥劑也是一大消耗,國外的一些儀器,每次都一個COD或氨氮樣品需要20元或更高的價格成本,而國內的僅需要一塊多錢到兩塊多錢的樣子,相比來說,國內的檢測儀器有著明顯的優勢。

            在了解了國內外的水質檢測儀器市場現狀,您是否還在鐘愛“國外儀器”呢?所謂進口儀器,尤其是對于COD快速測定儀、氨氮測定儀、總磷快速測定儀、總氮快速測定儀等水質檢測儀器來說,那僅僅是歷史遺留的“名聲”罷了,我們可以很自豪的宣布:對于國內企業選擇來說,國內的水質檢測儀器,已經不比國外差。

            COD快速測定儀、氨氮快速測定儀、總磷快速測定儀、總氮快速測定儀等水質檢測儀器已經逐漸地引領水質檢測行業新方向,社會在發展,經濟在發展,技術也在不斷地更新,相信不久的將來,我國的水質儀器一定會走向世界的巔峰水平。

            COD快速測定儀準不準?哪個品牌好?

              

            成都丁當科技有限公司,作為一家專業水質分析儀器制造商,主要產品包含有COD測定儀、氨氮測定儀、總磷測定儀、總氮測定儀、重金屬測定儀等。今天就帶大家了解一下丁當牌水質分析儀器的特點。

            首先,丁當牌所有水質分析儀器,各項參數測定指標完全依據國家或國際上通用的相關標準進行研發,保證測量結果準確有效,適用于國內眾多檢測標準。

            其次來看,針對不同用戶對于水質分析儀器的不同需求,丁當水質分析儀器有三種款式可供選擇,分別有實用型水質測定儀、經濟型水質測定儀以及便攜式水質測定儀。

            如果用戶對于測定精度要求不高的話,我們建議選擇經濟型;如果是經常性室外操作那推薦選擇便攜式,可以選配便攜打印機,更加方便攜帶適合戶外水質測定工作者;實驗室常用推薦為打印型水質測定儀,自帶打印機功能,可以實時打印當前測定數據以及歷史存儲數據。

            在方便儀器操作人員的使用方面,丁當牌水質分析儀器配備有專業的耗材試劑,使得水樣的測定過程更加便捷、簡單;同時采用比色管比色,消解比色一體,無需換管,使測定操作過程更加簡單、安全。

            儀器相關性能方面,采用進口高亮度長壽命冷光源,光學性能極佳,壽命可長達10萬個小時,確保儀器使用過程中的可靠性。

            人機交互界面更加便捷,大屏LCD中文直觀顯示,同時內置多條標準曲線,能夠直接取水樣進行測定,測量結果能夠直觀顯示,數據直讀,顯示數據包含有:當前日期、當前時間、測定參數、測定數據以及檢測結果等。

            具有大容量的數據儲存功能,可以儲存1800條測定數據,并且可以自由查看歷史檢測數據并打印,與此同時,帶有USB接口,能夠將數據上傳至電腦端,這樣方便用戶對歷史數據進行查看分析。

            具有曲線覆蓋干涉功能,防止個人誤操作覆蓋曲線;與此同時丁當牌水質分析儀器還具有一鍵恢復出廠設置功能,當不小心將曲線誤刪除以后,能夠保證隨時恢復刪除以及覆蓋的標準曲線,為客戶提供了更加人性化的設置。

            丁當水質分析儀器還有很多功能特點,今天就先帶您了解最基本的一些,如需詳細資料,

            請登陸http://www.672352.com/查看,如果您對我們的產品感興趣或者有相關問題咨詢,聯系我們的客服人員為您解答。


            丁當科技COD快速測定儀標準曲線



            總氮去除投加乙酸鈉信息

            比總氮去除投加乙酸鈉價格選總氮去除投加乙酸鈉型號,專業總氮去除投加乙酸鈉制造公司丁當科技1臺總氮去除投加乙酸鈉也批發而總氮去除投加乙酸鈉報價合理,咨詢總氮去除投加乙酸鈉到5117水質測定網。

            總氮去除投加乙酸鈉相關推薦

            亚洲中文字幕日产乱码2020